SMART X96-5E

EasyClick & Standard Metering

SIngle/Three Phase 1/5A CT Operated MID (Basic Range)

Features
  • MID Certified to Class C (0.5%) accuracy
  • 1/5A Current transformer operated
  • Total Harmonic Distortion (Amps)
  • Total Harmonic Distortion (Volts)
  • Highly visible backlit display from all angles
  • Programmable reverse flow for right/left side of breaker CT installation.
  • Built in Modbus and Pulsed outputs
Displayed Parameters
  • Phase to Neutral Voltage (V)
  • Phase to Phase Voltage (V)
  • Phase Current (A)
  • Voltage Total Harmonic Distortion (U%THD)
  • Current Total Harmonic Distortion (I%THD)
  • Frequency (Hz)
  • Power Factor (PF)
  • Current Max Demand (MD A)
  • Power Max Demand (MD kW)
  • Active Power (kW)
  • Reactive Power (kVAr)
  • Apparent Power (kVA)
  • Import Active Energy (kWh)
  • Export Active Energy (kWh)
  • Total Active Energy (kWh)
  • Import Reactive Energy (kVArh)
  • Export Reactive Energy (kVArh)
  • Total Reactive Energy (kVArh)
Product information

The Smart X96-5E is a high accuracy multifunction power meter that is a traditional wired 1/5A current transformer operated meter.. Configurable for 1p2w, and 3p4w systems and hosting a vast range of measuring parameters such as Amps, Volts, Power, Power and Current Demand, Power Factor, Imported and Exported kWh, Phase Sequence and a Phase Summary page.  It is one of the most user-friendly multifunction power meters in the market form installation to end client use.  The SMART X96-5E does not have the Individual harmonics, internal three phase supply (Powered from L1 & N internally), voltage output and can not be used in 3p3w applications. 

It is typical in most installations that the current transformers are mounted on the left-hand side of the breaker so P1 is facing the correct way. However, it is also possible to mount the current transformer on the right-hand side with P2 facing the breaker. This is possible due to the meter having the option to reverse the flow to correct this type of application.  

The SMART X96-5E requires mains voltage inputs and external current transformers in order to operate, it is self-supplied. The Smart X96-5E meter comes complete with RS485 Modbus RTU and dual pulsed outputs as standard.  

Certifications & Standards
  • MID: EN50470-1 & EN50470-3 Class B & C
  • EMC: EN61326-1 & EN61326-2-3
  • LVD: EN61010-1 & EN61010-2-3
  • IEC/EN62052-11:2003 Class 0.5s