Back to products

SMART X96-1E

EasyClick & Standard Metering

Three Phase EasyClick MID (Basic Range)

Features
  • MID Certified to Class C (0.5%) accuracy
  • EasyClick technology for plug in current transformer and mains voltage connection
  • Elimination of wiring errors & labour saving
  • Designed and tested in the UK by an independent laboratory
  • Highly visible backlit display from all angles
  • Programmable reverse flow for right/left side of breaker CT installation.
  • Built in Modbus and Pulsed outputs
Displayed Parameters
  • Phase to Neutral Voltage (V)
  • Phase to Phase Voltage (V)
  • Phase Current (A)
  • Voltage Total Harmonic Distortion (U%THD)
  • Current Total Harmonic Distortion (I%THD)
  • Frequency (Hz)
  • Power Factor (PF)
  • Current Max Demand (MD A)
  • Power Max Demand (MD kW)
  • Active Power (kW)
  • Reactive Power (kVAr)
  • Apparent Power (kVA)
  • Import Active Energy (kWh)
  • Export Active Energy (kWh)
  • Total Active Energy (kWh)
  • Import Reactive Energy (kVArh)
  • Export Reactive Energy (kVArh)
  • Total Reactive Energy (kVArh)
Product information

The Smart X96-1E is a high accuracy multifunction power meter that has been developed with plug in connections for the current transformer and mains voltage supply inputs. This negates the need to traditional wire into the meter and saving 90% on labour as well as eliminating wiring errors. Configurable for 1p2w, and 3p4w systems and hosting a vast range of measuring parameters such as Amps, Volts, Power, Power and Current Demand, Power Factor, Imported and Exported kWh, Phase Sequence and a Phase Summary page.  It is one of the most user-friendly multifunction power meters in the market form installation to end client use.  The SMART X96-1E does not have the Individual harmonics, internal three phase supply (Powered from L1 & N internally), voltage output and can not be used in 3p3w applications. 

It is typical in most installations that the current transformers are mounted on the left-hand side of the breaker so P1 is facing the correct way. However, it is also possible to mount the current transformer on the right-hand side with P2 facing the breaker. This is possible due to the meter having the option to reverse the flow to correct this type of application.  

The SMART X96-1E requires mains voltage inputs and external current transformers in order to operate, it is self-supplied. The Smart X96-1E meter comes complete with RS485 Modbus RTU and dual pulsed outputs as standard.   

Certifications & Standards
  • MID: EN50470-1 & EN50470-3 Class 0.5
  • EMC: EN61326-1 & EN61326-2-3
  • LVD: EN61010-1 & EN61010-2-3
  • IEC/EN62052-11:2003 Class 0.5s
Downloads

Not yet registered or logged in? Click below to register or login to enable access to Eastron’s full range of product data sheets, manuals, MID certificates and protocol specification pdf downloads.