MCS-U22
MultiClick Multi Circuit Monitoring
Voltage and Communication Module
- Product videos
- Product variants
- MCS-U20 - Phase to phase and phase to nuetral voltage & frequency
- MCS-U21 - Phase to phase and phase to nuetral voltage, frequency, THD & alarm threshold
- MCS-U22 - Phase to phase and phase to nuetral voltage, frequency, THD, alarm threshold and RS485 Modbus output
- Features
- 2 Module DIN rail mounted
- Can measure and monitor upto 32 x three phase or 96 x single phase circuits
- One voltage reference required for upto 32 x three phase circuits
- RJ12 Plug in CT ports for fast and easy installation
- RJ45 plug in ports for interconnection of devices
- Product information
This new concept of intelligent measuring and monitoring of power management and distribution has been designed and engineered for new and retro fit applications. Up to 32 x Three Phase or 96 x Single Phase circuits measured and accessible from one centralized data display. The current, Power and Energy is monitored by the MCS-I module, which has three RJ12 inputs for three individual split core sensors or alliteratively you can just the first RJ12 input, if using our three-phase block sensor. There are three different levels of the MCS-I modules ranging from basic measurement to THD (Total Harmonic Distortion), power per phase and overload alarm functions. The MCS-I modules can then be interconnected via the RJ45 input/ output back to the Voltage and communication module (MCS-U) You can have up to 32 x MCS-I modules connected on one bus (32 x three phase or 96 x single phase circuits). There is no voltage reference required for the MCS-I module.
The MCS-U module is the Voltage and Communication module, you will connect your voltage reference for the complete system to this device (1ph2W or 3ph4W). It will be interconnected to the MCS-I module and the display Module (MCS-D) via RJ45 input / output ports. In the event you do not require a display, you can utilize the RS485 output on this module to program or to connect into a BMS system or energy management platform (Connex). Depending on the level of requirements we can provide a basic 96x96mm display which will measure the multiple circuits, it can also be used for the setting up of the entire system. Alternatively, we can offer a HMI screen which in conjunction with our Eastron ConneX, which can be used as a centralised metering data point or as a sub metering remote monitoring and data logging end to end solution
- Certifications & Standards
- EN60253-22 Class 0.5s & EN61557-12 Class 0.5
- EMC: EN61326-1 & EN61326-2-3
- LVD: EN61010-1 & EN61010-2-3